APPLICATIONS
Four JDR0.085 electric clean steam generators, each rated at 85 kg/h of steam at 1.0 MPa, were supplied to a laboratory in Russia. The units are mounted on 304 stainless steel skids with castors, fully pre-piped before shipment, controlled by Siemens PLC touchscreens, and factory-tested before dispatch.

The laboratory distributes steam to several points rather than concentrating demand in one central plant, so capacity was split into four smaller generators instead of a single large unit. Each unit runs independently, which keeps steam available while another is being serviced. Because piping and valves are connected before shipment, site work is reduced to connecting water, power and drain.
Model | JDR0.085 electric clean steam generator |
Quantity | 4 units |
Rated capacity | 85 kg/h steam per unit |
Design pressure | 1.0 MPa (=10 bar) |
Steam condition | Saturated steam, approx. 180 °C at 1.0 MPa |
Heating method | Electric resistance heating; no fuel and no flue gas at the point of use |
Power supply | 400 V / 50 Hz / 3 phase |
Installed power | 60 kW per unit |
Shell, inner vessel, valves | 316 stainless steel |
Feed water pump | 304 stainless steel |
Valve set | Blowdown valve, pressure controller, safety valve, bottom valve, check valve |
Blowdown | Automatic |
Control | Siemens PLC with touchscreen HMI |
Water treatment | Integrated pure water module (PUNP) |
Tanks | 316 stainless steel feed water tank and blowdown tank |
Frame and mobility | 304 stainless steel skid frame with castors |
Piping base | 304 stainless steel valve base; 316 stainless steel connecting piping and valves |
Testing | Factory Acceptance Test (FAT) completed before shipment |

1. Why Using Clean Steam Generator in Laboratory ?
① No boiler chemicals in the steam. ② Electric heating produces no flue gas, which suits laboratory rooms that have no boiler house or chimney. ③ Movable, right-sized units. it can be repositioned when laboratory layouts change.
2. What is the electrical consumption of an 85 kg steam generator?
The units draw about 60 kW each at full load.
Formula for calculating the electrical consumption of steam generator: Steam capacity (kg/h) × 0.72 ≈ electrical power (kW). Example: 85 kg/h × 0.72 ≈ 61 kW.
Suri Zhao, Industrial Boiler Consultant
Email: suri@yuanda-boiler.com | WhatsApp / WeChat: +86 18703633064
Clean Steam Generator Webpage: JDR CLEAN STEAM GENERATOR
Electric Steam Generator Webpage: LDR ELECTRIC STEAM GENERATOR
Related Cases: Standard Electric Steam Generator for Laundry
Versión en español → 4 unidades generadores de vapor limpio 85kg para laboratorio ruso
Henan Yuanda Boiler Corporation Ltd. has manufactured industrial steam, hot water and thermal oil boilers since 1956, holds ASME, CE, EAC and DOSH certificates, and has supplied equipment to more than 135 countries.
We have done many steam generator projects across Asia, Latin-America, Middle-east and Africa. Welcome to Consult.